In this crucial installment of our Rack Refrigeration Cycle series, Matthew Taylor covers Subcooler and Liquid Pressure Regulator. Learn why mechanical subcooling is crucial for system efficiency and how it can dramatically reduce power consumption - showing how the same cooling load can be achieved with 4.5 HP instead of 15 HP!
Key topics covered:
How subcoolers improve system efficiency and reduce energy costs
Understanding plate heat exchangers and counterflow design
Proper setup and adjustment of subcooler TXVs
Common troubleshooting challenges and solutions
Modern electronic valve control systems vs. mechanical setups
Best practices for technicians working with subcooled systems
This presentation includes real-world examples and practical tips for service technicians, including why you should never adjust TXVs with the subcooler off and how to properly diagnose flooding issues.
#HVAC #Refrigeration #HVACEducation #CommercialRefrigeration #HVACTrain #SubcoolingSystem
Buy your tickets or learn more about the 6th Annual HVACR Training Symposium at .