ACFM vs SCFM 3D

  • Видео
  • О видео
  • Скачать
  • Поделиться

ACFM vs SCFM 3D

In this 3D video, we show the differences between ACFM vs SCFM, also known as actual cubic feet per minute and standard cubic feet per minute, respectively. Both are means of quantifying airflow, but they show the difference between mass flow rate and volume flow rate. CFM represents cubic feet per minute, which can represent a 1’ x 1’ x 1’ box of air. The blower moves hundreds of these boxes per minute. That air may have varying temperature or humidity levels. The standard CFM (SCFM) conditions consist of air at 68.3 degrees Fahrenheit and 0% humidity at atmospheric pressure. A cubic foot of air will weigh 0.075 pounds under these conditions, but this weight will change when there are changes in temperature, pressure, and humidity. HVAC systems also move several boxes of air, with each one exerting force on the others. The air we breathe primarily consists of nitrogen (78%) and oxygen (21%), plus some trace substances. These molecules move faster when we apply heat, making them more spaced out and less dense, which reduces the weight of a cubic foot of air. Water vapor (humidity) weighs less than diatomic nitrogen and oxygen in the atmosphere, so higher humidity levels will reduce the weight of a cubic foot of air. Lower pressures, such as at high elevations, will make the air less dense, which will also decrease the weight of a cubic foot of air. For those reasons, the 400 CFM per ton rule of thumb is not applicable to all climates. We want to focus on maintaining a fixed mass flow rate, which accounts for the weight of each cubic foot of air. ACFM accounts for the weight of the air we’re moving to account for variations in humidity, altitude (pressure), and temperature. Arid climates are likely to have higher target ACFM rates, and humid climates are likely to have lower target ACFM rates. SCFM is a common reference point during the commissioning and testing of equipment, and ACFM is more likely to give us a nuanced idea of the pounds of air our systems are moving. Buy your virtual tickets or learn more about the HVACR Training Symposium at https://hvacrschool.com/symposium. Read all the tech tips, take the quizzes, and find our handy calculators at https://www.hvacrschool.com/.
31, 660   |   1 год. назад  |   968 - 0
 

ACFM vs SCFM 3D

Скачайте изображение (превью) выбрав качество


320x180 480x360 640x480 1280x720

In this 3D video, we show the differences between ACFM vs SCFM, also known as actual cubic feet per minute and standard cubic feet per minute, respectively. Both are means of quantifying airflow, but they show the difference between mass flow rate and volume flow rate.

CFM represents cubic feet per minute, which can represent a 1’ x 1’ x 1’ box of air. The blower moves hundreds of these boxes per minute. That air may have varying temperature or humidity levels. The standard CFM (SCFM) conditions consist of air at 68.3 degrees Fahrenheit and 0% humidity at atmospheric pressure. A cubic foot of air will weigh 0.075 pounds under these conditions, but this weight will change when there are changes in temperature, pressure, and humidity. HVAC systems also move several boxes of air, with each one exerting force on the others.

The air we breathe primarily consists of nitrogen (78%) and oxygen (21%), plus some trace substances. These molecules move faster when we apply heat, making them more spaced out and less dense, which reduces the weight of a cubic foot of air. Water vapor (humidity) weighs less than diatomic nitrogen and oxygen in the atmosphere, so higher humidity levels will reduce the weight of a cubic foot of air. Lower pressures, such as at high elevations, will make the air less dense, which will also decrease the weight of a cubic foot of air.

For those reasons, the 400 CFM per ton rule of thumb is not applicable to all climates. We want to focus on maintaining a fixed mass flow rate, which accounts for the weight of each cubic foot of air. ACFM accounts for the weight of the air we’re moving to account for variations in humidity, altitude (pressure), and temperature. Arid climates are likely to have higher target ACFM rates, and humid climates are likely to have lower target ACFM rates. SCFM is a common reference point during the commissioning and testing of equipment, and ACFM is more likely to give us a nuanced idea of the pounds of air our systems are moving.

Buy your virtual tickets or learn more about the HVACR Training Symposium at .

Read all the tech tips, take the quizzes, and find our handy calculators at .


ACFM vs SCFM 3D

Чтобы скачать видео "ACFM vs SCFM 3D" передвинте ползунок вправо



Покажите вашим друзьям, добавьте в соцсети

Ссылка на страницу с видео:

 

Ссылка HTML на страницу с видео:

 

Код для вставки плеера:


  • Комментарии

Комментарии ФБ


Уважаемые друзья!

Источником всего видеоконтента, в том числе проигрывающегося на страницах ресурса ruslar.me, является сторонний видео ресурс, а именно общедоступный видеохостинг YouTube.com, предоставляющий открытый доступ к своему видеоконтенту (используя открытую и общедоступную технологию video API3 youtube.com)!

Проблемы с авторскими правами

Если вам принадлежат авторские права на данное видео, которое было загружено без вашего согласия на YouTube.com, перейдите на страницу этого видео сайта YouTube.com , нажмите на ссылку под проигрывателем Ещё -> "Пожаловаться" -> "Нарушение моих прав" и в выпадающем меню, выбирите, что именно нарушается и нажмите кнопку "Отправить".



Неприемлемый контент

Чтобы сообщить о неприемлемом видео, перейдите на YouTube, нажмите на ссылку под проигрывателем Ещё -> "Пожаловаться" и выберите в "Сообщить о нарушении" что именно вас не устраивает в этом видео. Подробнее о наших правилах читайте в Условиях использования.