Jason Obrzut, Don Gillis, and Dr. Chuck Allgood give a flammable refrigerant update at the 2023 HVACR Training Symposium. They talk about the latest news regarding regulatory updates and the transition to low-GWP A2L refrigerants. The AIM Act mandates the phasedown of high-GWP HFCs federally (state regulations may vary a little bit, but all of them will have an HFC phasedown); in the end, production will be decreased by 85%, meaning that there is not a total refrigerant phaseout. Recovery and reclamation will be crucial. R-32, an A2L refrigerant, has been used in window and package units, and R-1234yf has also been used industrially and in automobiles. Most A2Ls going to market will include those refrigerants and refrigerant blends. Installation and design standards will be tailored to the A2L refrigerants. A2Ls are nowhere near flammable as A3s, including propane. ASHRAE Standard 34 establishes a lettering and numbering system based on toxicity (A or B) and flammability (1, 2L, 2, and 3). Non-toxic refrigerants have the letter A, and toxic ones have the letter B. Non-flammable refrigerants under test conditions receive the number 1, mildly flammable receive 2L, moderately flammable receive 2, and highly flammable refrigerants receive 3. We have largely been working with A1 refrigerants, like R-22 and R-410A. A2Ls are non-toxic but propagate a small flame under test conditions; A2Ls are significantly less flammable than A3s, like hydrocarbons, which is evident in Dr. Chuck’s flask test. Flammability also depends on properties like the minimum ignition energy, the heat of combustion, and the burning velocity. A2Ls take a lot more energy to ignite than A3s, and their heat of combustion and burning velocity values are quite low by comparison. The industry is moving to A2Ls to minimize risk (as opposed to A3s). Systems for A3 refrigerants typically have smaller charges than other systems with lower flammability to minimize risk. We will start seeing new tanks with special safety features, including ones with spring-loaded pressure relief valves that can open and close automatically if the pressure gets too high. You’ll likely see left-handed threads on some tanks, and adapters may become available for them. Recovery tanks will also have a red stripe, and you can decommission tanks by puncturing them (not with a ruptured disc). Refrigerant tanks will come in neutral colors and have shrink wrap to prevent counterfeit refrigerant from entering circulation, and the refrigerant name will be labeled on the tank. Some of the best (albeit not required) practices for A1s will be required for A2Ls. These include purging the system with nitrogen, evacuation, and leak/pressure testing. Otherwise, the refrigerants have very similar pressures to R-410A, and working on systems with A2L systems will be similar to working on R-410A systems. You can email questions to Don at don.gillis@chemours.com. You may also check out Opteon’s website at https://www.opteon.com/en, AHRI’s Safe Refrigerant Transition Task Force at https://www.ahrinet.org/advocacy/safe-refrigerant-transition-task-force, and educational resources on ESCO Group’s HVACR Learning Network at https://hvacr.elearn.network/. Buy your virtual tickets or learn more about the HVACR Training Symposium at https://hvacrschool.com/symposium. Read all the tech tips, take the quizzes, and find our handy calculators at https://www.hvacrschool.com/.
27, 187   |   2 год. назад  |   673 - 0
 

Flammable Refrigerant Update

Скачайте изображение (превью) выбрав качество


320x180 480x360 640x480 1280x720

Jason Obrzut, Don Gillis, and Dr. Chuck Allgood give a flammable refrigerant update at the 2023 HVACR Training Symposium. They talk about the latest news regarding regulatory updates and the transition to low-GWP A2L refrigerants.

The AIM Act mandates the phasedown of high-GWP HFCs federally (state regulations may vary a little bit, but all of them will have an HFC phasedown); in the end, production will be decreased by 85%, meaning that there is not a total refrigerant phaseout. Recovery and reclamation will be crucial.

R-32, an A2L refrigerant, has been used in window and package units, and R-1234yf has also been used industrially and in automobiles. Most A2Ls going to market will include those refrigerants and refrigerant blends. Installation and design standards will be tailored to the A2L refrigerants. A2Ls are nowhere near flammable as A3s, including propane.

ASHRAE Standard 34 establishes a lettering and numbering system based on toxicity (A or B) and flammability (1, 2L, 2, and 3). Non-toxic refrigerants have the letter A, and toxic ones have the letter B. Non-flammable refrigerants under test conditions receive the number 1, mildly flammable receive 2L, moderately flammable receive 2, and highly flammable refrigerants receive 3.

We have largely been working with A1 refrigerants, like R-22 and R-410A. A2Ls are non-toxic but propagate a small flame under test conditions; A2Ls are significantly less flammable than A3s, like hydrocarbons, which is evident in Dr. Chuck’s flask test. Flammability also depends on properties like the minimum ignition energy, the heat of combustion, and the burning velocity. A2Ls take a lot more energy to ignite than A3s, and their heat of combustion and burning velocity values are quite low by comparison. The industry is moving to A2Ls to minimize risk (as opposed to A3s). Systems for A3 refrigerants typically have smaller charges than other systems with lower flammability to minimize risk.

We will start seeing new tanks with special safety features, including ones with spring-loaded pressure relief valves that can open and close automatically if the pressure gets too high. You’ll likely see left-handed threads on some tanks, and adapters may become available for them. Recovery tanks will also have a red stripe, and you can decommission tanks by puncturing them (not with a ruptured disc). Refrigerant tanks will come in neutral colors and have shrink wrap to prevent counterfeit refrigerant from entering circulation, and the refrigerant name will be labeled on the tank.

Some of the best (albeit not required) practices for A1s will be required for A2Ls. These include purging the system with nitrogen, evacuation, and leak/pressure testing. Otherwise, the refrigerants have very similar pressures to R-410A, and working on systems with A2L systems will be similar to working on R-410A systems.

You can email questions to Don at don.gillis@chemours.com. You may also check out Opteon’s website at , AHRI’s Safe Refrigerant Transition Task Force at , and educational resources on ESCO Group’s HVACR Learning Network at .

Buy your virtual tickets or learn more about the HVACR Training Symposium at .

Read all the tech tips, take the quizzes, and find our handy calculators at .


Flammable Refrigerant Update

Чтобы скачать видео "Flammable Refrigerant Update" передвинте ползунок вправо



Покажите вашим друзьям, добавьте в соцсети

Ссылка на страницу с видео:

 

Ссылка HTML на страницу с видео:

 

Код для вставки плеера:


  • Комментарии

Комментарии ФБ


Уважаемые друзья!

Источником всего видеоконтента, в том числе проигрывающегося на страницах ресурса ruslar.me, является сторонний видео ресурс, а именно общедоступный видеохостинг YouTube.com, предоставляющий открытый доступ к своему видеоконтенту (используя открытую и общедоступную технологию video API3 youtube.com)!

Проблемы с авторскими правами

Если вам принадлежат авторские права на данное видео, которое было загружено без вашего согласия на YouTube.com, перейдите на страницу этого видео сайта YouTube.com , нажмите на ссылку под проигрывателем Ещё -> "Пожаловаться" -> "Нарушение моих прав" и в выпадающем меню, выбирите, что именно нарушается и нажмите кнопку "Отправить".



Неприемлемый контент

Чтобы сообщить о неприемлемом видео, перейдите на YouTube, нажмите на ссылку под проигрывателем Ещё -> "Пожаловаться" и выберите в "Сообщить о нарушении" что именно вас не устраивает в этом видео. Подробнее о наших правилах читайте в Условиях использования.